Company Address
No. 6668, Section 2, Qingquan Road, Qingbaijiang Dist., Chengdu, Sichuan, China
● Product Parameters
MODEL | MIG-270K | MIG-350K | ||||
Rated Input Voltage(V) | 1P 220V | 3P 220V | 3P 380V | 1P 220V | 3P 220V | 3P 380V |
Frequency(Hz) | 50/60 | 50/60 | ||||
Max Input Current(A) | 27 | 14 | 16 | 39 | 20 | 23 |
Rated Input Capacity(KVA) | 5.3 | 10.3 | 7.6 | 15.3 | ||
No-Load Voltage(V) | 54 | 62 | ||||
Adjustment Current range(A) | 40-170 | 40-250 | 40-220 | 40-350 | ||
Rated Working Voltage(V) | 23 | 27.5 | 25 | 31.5 | ||
Duty Cycle(%) | 60 | 60 | ||||
MMA function | YES | YES | ||||
Wire Feeder | built-in | |||||
Wire Diamter(MM) | 0.8-1.0 | 0.8-1.0 | 0.8-1.0 | 0.8-1.0 | 0.8-1.0 | 0.8-1.2 |
Protection classification | IP21 S | IP21S | ||||
Net Weight (KG) | 30 | 32 | ||||
Machine Dimensions(MM) | 660x280x555 | 660x280x555 |
● IGBT Inverter Automatic Submerged Arc Welding Machine
1) The installation area should be firm enough to support the welder.
2) It is forbidden to install the welder in places wherewater splashes may be generated,such as water pipes. 3) Welding operations must be performed in a relatively dry environment where the air humidity is normally not greater than 90%.
4) The ambient temperature shall be between-10°C and +40°C.
5) Do not perform welding in dusty or corrosive gas-containing areas.
6)Do not place the welder on a tabletop with an inclination greater than 15°.
The welder has been installed with overvoltage, overcurrent and overheating protective circuits. When the grid voltage, output current and internal temperature exceed the set standards, the welder will stop working automatically;but excessive use (such as excessivevoltage) will still cause damage to the welder, so the following matters shall be noticed:
● Prohibit excessive voltage
In general,the automatic voltage compensation circuitinside the welder will ensure that the welding current is kept within the allowable range. If the supply voltageexceeds the allowable value,it will damage the welder.
● Prohibit overload
Operators shall use the welder according to its allowable load duration rate and maintain the welding current within the maximum allowable load current. Current overload will remarkably shorten the life of the welder or even burn it.
If the welder exceeds the standard load duration rate inworking,it may suddenly enter the protection state and stop working. This indicates that once the standard load duration rate is overtaken, it will heat up to trigger the temperature control switch to stop the welder,and theyellow indicator light on the front panel is on at the same time. In this case, do not pull out the power plug. Letthe fan cool down the welder.When the yellow indicator light is off and the temperature drops to the standard range,start welding.